From: Saul Perlmutter (saul@lbl.gov)
Date: Mon Apr 05 2004 - 21:30:52 PDT
Does anybody have any more examples of Adam's I band magnitudes? This
I band difference between us and Adam for the two examples shown is a
little too close to the difference between Type Ia and II for comfort.
Greg Aldering wrote:
>Vitaliy and I looked at whether the zeropoint corrections just sent
>by Rob bring our photometry into agreement with that of Adam. Here
>is a comparison table
>
> Zorig Zapcor Zcorr ZAdam Diff | Iorig Iapcor Icorr IAdam Diff
> ----------------------------------------------------------------------------
> -076 24.52 0.57 25.09 25.1 0.0 | 25.96 0.59 26.55 26.8 -0.3
> -177 24.61 0.81 25.42 25.2 0.2 | 25.52 0.72 26.24 26.65 -0.41
> -096 24.90 0.73 25.63 25.5 0.1 |
>
>Look at the "Diff" columns; the corrections look good in Z-band. In
>I-band there is still a hint of a systematic (note the I-band magnitude
>uncertainties are 0.2-0.3 mag, so this is just a hint).
>
>- G & V
>
>
This archive was generated by hypermail 2.1.4 : Mon Apr 05 2004 - 21:31:23 PDT