Re: question for HST paper

From: Reynald Pain (Reynald.Pain@in2p3.fr)
Date: Fri May 02 2003 - 06:02:38 PDT

  • Next message: Isobel Hook: "HST paper - Isobel's comments part #1"

    Hi,

    Concerning 1998ay/98104 and 1998be/9878. Judging from figure 1+2, it
    is not obvious that their lightcurve are well fit with the Ia template.
    Look at the points near max of the R LC (only past max data in I).

    Reynald
    _____________________________________________________________________
    R. Pain - LPNHE, Universites Paris VI & VII, 4 Place Jussieu - T33 RdC
    75252 Paris cedex 05 - Tel: +33 1 44 27 72 53 Fax: +33 1 44 27 46 38

    On Thu, 1 May 2003, Peter Nugent wrote:

    > > We have to make sure we don't get into circular arguments while
    > > eg first using colors to type it, and then use same colors to
    > > limit reddening.
    >
    > Fortunately for us SNe Ia are much bluer than Ib/c's and their color
    > evolution is different as well so reddening and typing isn't a
    > circular task.
    >
    > Now as for Rob's statement about the categories these should fall in.
    >
    > The color of a Ib/c at this z should be R-I>=0.8 before peak and it gets
    > redder continuously. A Ia should have a color around R-I>=0.3-0.4 with a
    > little slop due to choice of uberspectrum and stretch (a bluer one like
    > Rob used for all his analysis makes it around 0.3, what I and the Israelis
    > used puts it around 0.4) and the color curves are very different. Your
    > measurements of the color (including all possible arbitrary systematics,
    > like using both uberspectra for the k-corrs) for these SNe are better than
    > 0.1 mag. Thus according to the paper I cited (and their nice interactive
    > website) and what I checked out on my own, the colors and their evolution
    > are consistent with them both being Ia's at => 3 sigma. As Rob pointed
    > out, they fit his Ia color curves nicely.
    >
    > Thus they should definitely go into the 'good' Ia category, because I
    > think this is at the same level as the id'ing of the spectra as 'good'.
    > And remember, the spectra are not-inconsistent with Ia's, they are just
    > not that good S/N-wise, so there is no negative from them, just no
    > positive either.
    >
    > Now before Saul says, 'Why don't we do this for the other SNe from P99 we
    > threw out?' the simple answer is we can't since we in general have just 1
    > color at peak (not 4-5 spread out) and their error bars on that 1 color
    > are horrendous.
    >
    > Thus add my paragraph in where you id them and we are good to go as-is.
    >
    > Cheers,
    >
    > Peter
    >
    > --
    > Peter E. Nugent
    > Staff Computational Scientist - Scientific Computing Group - NERSC
    > Lawrence Berkeley National Laboratory
    > M.S. 50F-1650 - 1 Cyclotron Road - Berkeley, CA, 94720-8139
    > Phone:(510) 486-6942 - Fax:(510) 486-5812
    > E-mail: penugent@LBL.gov - Web: http://supernova.LBL.gov/~nugent
    >
    >
    >
    >



    This archive was generated by hypermail 2.1.4 : Fri May 02 2003 - 05:43:28 PDT