Re: late-time fitting debate

From: Robert A. Knop Jr. (robert.a.knop@vanderbilt.edu)
Date: Sat Mar 15 2003 - 13:03:16 PST

  • Next message: Robert A. Knop Jr.: "Re: late-time fitting debate"

    On Sat, Mar 15, 2003 at 02:41:45PM -0600, Robert A. Knop Jr. wrote:
    > I like this approach and am happy with it, if everybody else accepts
    > it. (I'll use an 0.007 error floor unless I hear otherwise.)

    Note that I meant 0.007 times the peak flux value in the lightcurve.
    (By which I mean "brightest data point" rather than "flux at maximum",
    simply because the former is so much easier to implement.)

    -Rob

    -- 
    --Prof. Robert Knop
      Department of Physics & Astronomy, Vanderbilt University
      robert.a.knop@vanderbilt.edu
    